產品名稱:

差分探頭|P7360A

更新時間:2024-09-07

產品型號:P7360A

產品報價:

產品特點:差分探頭|P7360A Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while

P7360A差分探頭|P7360A的詳細資料:

差分探頭|P7360A

差分探頭|P7360A

  • Signal Fidelity
    • >12.5 GHz Bandwidth (P7313, Typical)
    • >8.0 GHz Bandwidth (P7380A, Typical)
    • >6.0 GHz Bandwidth (P7360A, Typical)
    • >4.0 GHz Bandwidth (P7340A, Typical)
  • Extended Linear Dynamic Range
    • 1.25 Vp-p at 5x Attenuation (P7313)
    • 4 Vp-p at 25x Attenuation (P7313)
    • 2 Vp-p at 5x Attenuation (P7380A, P7360A, P7340A)
    • 5 Vp-p at 25x Attenuation (P7380A, P7360A, P7340A)
  • Low Probe Loading
    • DC Input Resistance
      • 100 kΩ Differential
      • 50 kΩ Single Ended
    • AC Loading
      • Zmin >200 Ω out to 10 GHz (P7313)
      • Zmin >290 Ω, 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
  • Versatility
    • Make Differential or Single-ended (Ground-referenced) Measurements*1
    • Solder-down Capability
    • Handheld Probing with Variable Spacing and Compliance
    • Fixtured Probing
  • Interchangeable Tip-Clip™ Assemblies
    • Connect to a Variety of Devices
    • Economical
  • TekConnect® Interface

Applications

  • Examples Include, but are not Limited To:
    • PCI-Express I and II, Serial ATA II, USB 2.0, DDRII, DDRIII, Fireware 1394b, Rambus, XAUI

*1 For details, please see application note 60W-18344-0, “Making Single-ended Measurements with Differential Probes.”

Z-Active™ Probing Architecture Leads the Way for High-speed Probing Applications

Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.

The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high-frequency loading of Z0 probes.

Signal Fidelity

You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:

  • High Bandwidth
  • Excellent Step Response
  • Low Loading
  • High CMRR
  • Extended Linear Dynamic Range

Extended Linear Dynamic Range

Many of today’s logic signals and serial bus signals require the capability to measure up to several volts peak to peak.  These voltage levels may easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range.  With a 2.0 Vp-p linear dynamic input range at the 5x attenuation setting, you can accuray measure DDR II and III, Firewire 1394b, and PCI-Express I and II signals at reduced noise levels.  In addition the 25x attenuation setting’s linear dynamic input voltage range can be used up to 5.0 Vp-p for accessing even larger signal swings found during transition times.

Connectivity

The Z-Active probe design allows the probe to easily switch between soldered, handheld, or fixtured applications.

This family of probes uses Tip-Clip™ assemblies, an interchangeable probe tip system that enables customers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. The several lengths and variable spacing of the assemblies provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips.

 

 如果你對P7360A差分探頭|P7360A感興趣,想了解更詳細的產品信息,填寫下表直接與廠家聯系:

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

滬公網安備 31011402002799號

主站蜘蛛池模板: 天天综合网在线| 天天爽天天爽| 日韩国产欧美一区二区三区在线| 亚洲欧美色图小说| 全午夜免费一级毛片| 欧美精品久久一区二区三区| 色噜噜狠狠狠狠色综合久不| 欧美日韩一区二区三区免费不卡| 涩涩成人免费视频| 欧美男女激情视频| 特级a级毛片| 亚洲精品伊人| 亚洲欧美日韩一区成人| 四虎影视国产精品婷婷| 欧美激情一二区| 生活片一级片| 欧美日韩大尺码免费专区| 香港三级日本三级韩国三级| 人人曰人人| 亚洲高清heyzo加勒比| 夜久久| 欧美区日韩区| 亚洲欧美日韩国产精品网| 亚洲天堂视频在线观看免费| 一级毛片免费在线| 亚洲视频免费一区| 四虎91视频| 亚州视频一区| 四虎4hu影库免费永久国产| 青草娱乐极品免费视频| 午夜蜜桃| 三级黄色片网址| 亚洲久热| 亚洲国产精品视频| 亚洲淫片| 青青伊人91久久福利精品| 亚洲视频在线观看| 欧美日韩国产精品| 四虎影视在线麻豆国产| 我想看一级毛片| 欧美久久天天综合香蕉伊 |